Medical Device Interoperability With Provable Safety Properties

Loading...
Thumbnail Image

Degree type

Doctor of Philosophy (PhD)

Graduate group

Computer and Information Science

Discipline

Subject

formal methods
interoperability
patient safety
Computer Sciences

Funder

Grant number

License

Copyright date

2019-08-27T20:19:00-07:00

Distributor

Related resources

Contributor

Abstract

Applications that can communicate with and control multiple medical devices have the potential to radically improve patient safety and the effectiveness of medical treatment. Medical device interoperability requires devices to have an open, standards-based interface that allows communication with any other device that implements the same interface. This will enable applications and functionality that can improve patient safety and outcomes. To build interoperable systems, we need to match up the capabilities of the medical devices with the needs of the application. An application that requires heart rate as an input and provides a control signal to an infusion pump requires a source of heart rate and a pump that will accept the control signal. We present means for devices to describe their capabilities and a methodology for automatically checking an application’s device requirements against the device capabilities. If such applications are going to be used for patient care, there needs to be convincing proof of their safety. The safety of a medical device is closely tied to its intended use and use environment. Medical device manufacturers create a hazard analysis of their device, where they explore the hazards associated with its intended use. We describe hazard analysis for interoperable devices and how to create system safety properties from these hazard analyses. The use environment of the application includes the application, connected devices, patient, and clinical workflow. The patient model is specific to each application and represents the patient’s response to treatment. We introduce Clinical Application Modeling Language (CAML), based on Extended Finite State Machines, and use model checking to test safety properties from the hazard analysis against the parallel composition of the application, patient model, clinical workflow, and the device models of connected devices.

Date of degree

2019-01-01

Date Range for Data Collection (Start Date)

Date Range for Data Collection (End Date)

Digital Object Identifier

Series name and number

Volume number

Issue number

Publisher

Publisher DOI

relationships.isJournalIssueOf

Comments

Recommended citation